Boiler locked out with a fault light or code? The checks to do before pressing reset, how resetting works on most boilers, why it keeps locking out and when to stop and call a Gas Safe engineer.

Quick Answer

To reset a boiler, first write down the fault code or light pattern, then check the pressure gauge reads at least 1 bar, that other gas appliances work and, in freezing weather, that the condensate pipe isn't frozen. Then press and hold the reset button, or turn the selector to the reset position, for the time your manual gives, usually a few seconds. Wait a few minutes for the boiler to go through its start-up. If it locks out again after two or three attempts, stop and call a Gas Safe engineer.

Key Takeaways

  • A reset clears a lockout. It does not fix whatever caused it, so always note the code first.
  • Low pressure, a frozen condensate pipe and no gas supply are the most common reasons a reset won't hold.
  • Two or three resets is the limit. Repeated resetting can hide a fault that needs attention.
  • Never reset a boiler if you smell gas, see soot or your CO alarm has gone off.
  • The first cold weeks of autumn bring the most lockouts, when a boiler that has idled all summer is asked to run for hours.
Boiler won't stay on after a reset?

Have the make, model and the exact fault code or light pattern ready. We'll talk you through it and confirm the price before a Gas Safe engineer starts any work.

Discuss a boiler repair →

To reset a boiler safely, note the fault code first, check the pressure is above 1 bar, make sure gas is reaching the house and, if it's freezing outside, check the condensate pipe. Then press and hold the reset button, or turn the selector to reset, for the few seconds your manual gives, and give the boiler a few minutes to fire. A reset clears a lockout but doesn't fix what caused it. If the boiler locks out again after two or three tries, stop resetting and get a Gas Safe engineer to look at it.

Check these before you reset

A boiler locks out when its own safety checks find something wrong and it shuts down rather than carry on. Pressing reset tells it to try again. If the problem is still there, it will simply lock out again, so a couple of minutes of checks first makes a successful reset far more likely.

  • Write down the code or light pattern. Take a photo of the display. The code is the most useful thing you can give an engineer, and some boilers clear it once you reset. Our boiler error codes guide explains what the common ones mean.
  • Check the pressure gauge. Most systems need about 1 to 1.5 bar when cold. Below 1 bar, the boiler will usually refuse to run, and resetting won't help until you top it up. Follow our steps on how to repressurise a boiler first.
  • Check the gas. Try the hob if you have gas cooking. If that won't light either, the problem is the gas supply or a prepayment meter that has run out, not the boiler.
  • Check the power. Make sure the fused spur next to the boiler is on and the display is lit. After a power cut, check the timer and thermostat haven't lost their settings.
  • Check the condensate pipe in cold weather. If the plastic pipe that runs outside has frozen, the boiler will lock out every time. Thaw it with warm (not boiling) water before resetting. Our guide to a frozen condensate pipe or blocked flue shows how.
  • Check the thermostat is calling for heat. Turn the room thermostat up a few degrees above room temperature and make sure the timer is on.

How to reset a boiler

The exact button varies by make and model, so check the user manual if you have it. Most manufacturers publish their manuals online under the model name printed on the front or underneath the boiler. The general process on most modern combi and system boilers is:

1

Find the reset control

It is usually a button marked "reset", a button with a flame symbol, or a position on the main selector dial. Some boilers use a combination of buttons, which the manual will show.

2

Press and hold for the time given

Most need a firm press held for a few seconds. Turning the boiler off and on at the mains switch is not the same as a reset on many models and may not clear a lockout.

3

Wait for the start-up

The boiler will run its fan and do its checks before trying to light. Give it at least five minutes. Run a hot tap or turn the heating up to give it a reason to fire.

4

Check it stays running

Watch the display and the pressure gauge for the next half hour. A small pressure rise as the system warms up is normal.

Resetting common boiler makes

The principle is the same across brands, but the controls and the way the fault is shown differ:

  • Worcester Bosch: many models show a code and a flashing light, and have a reset button on the control panel. If the blue light is flashing, see our guide to a Worcester boiler flashing blue light.
  • Vaillant: ecoTEC models show an F code and have a reset button. F28 and F29 are ignition and flame-loss faults that often follow a gas supply problem. See our guides to Vaillant F28 and Vaillant F29.
  • Ideal: many Logic and Vogue models show an F or L code and use a reset button or selector position. F1 is usually low pressure, covered in our Ideal F1 guide.
  • Older boilers with a pilot light: these don't reset in the same way. If the pilot has gone out, follow the relighting instructions on the boiler or read our guide on a pilot light that keeps going out.

Why a boiler keeps locking out

If the boiler fires after a reset but locks out again later, something is still wrong. The usual causes are:

  • Pressure dropping. If you keep having to top it up, there is a leak somewhere or the pressure relief valve is letting water go. See why a boiler keeps losing pressure.
  • Ignition or flame detection faults. A worn ignition electrode, a flame sensor that needs cleaning or a gas valve fault will cause repeated ignition lockouts.
  • Overheating. Sludge, a sticking pump or a partly closed valve can stop water moving through the boiler, so it overheats and shuts down. This is more common when the heating is first used after summer, because pumps and valves that have sat still for months can stick. Our guide on when to turn the heating on covers the checks worth doing before the first cold night.
  • Flue or condensate blockages. A blocked condensate trap or a flue restriction stops the boiler running safely.

Our article on a boiler that keeps turning off goes through these in more detail.

When not to reset

Don't reset the boiler if you can smell gas, a carbon monoxide alarm has gone off, you can see soot, scorch marks or a yellow flame, water is leaking from inside the casing, or it has already locked out two or three times. If you smell gas or your CO alarm sounds, turn the boiler off, open windows, get everyone outside and call the National Gas Emergency Service on 0800 111 999.

Don't remove the casing to look inside, and don't try to bypass or reset any internal overheat stat. Anything inside the boiler must be dealt with by a Gas Safe registered engineer. If your boiler is under warranty, check the terms before booking, because manufacturers often expect their own engineers or your installer to do repairs during the guarantee.

When you do call, give the make and model, the code, the pressure reading and what you have already checked. It helps the engineer arrive with the right expectations. Our labour is £95 an hour, the £60 call-out is waived when the job runs over 2 hours, and we confirm the price before starting. Read more about our boiler repair service and boiler lockout repairs.

Boiler locking out again?

Tell us the make, model and fault code. We'll explain the likely cause and confirm the price before any work starts.

📞 Call 020 7870 3200

Or see our boiler repairs and pricing.

Frequently Asked Questions

Is it safe to reset a boiler?

Yes, pressing the reset button is a normal user action that manufacturers include for this purpose. It is not safe to keep resetting a boiler that locks out again and again, and you should never reset it if you smell gas, see soot or scorch marks, or a carbon monoxide alarm has sounded.

How many times can you reset a boiler?

Two or three attempts is a sensible limit. If the boiler locks out again each time, the cause is still there, and repeated resets can make things worse or hide a fault. Stop, note the code and call a Gas Safe engineer.

How long does a boiler take to reset?

The button is usually held for a few seconds, then the boiler runs through its start-up checks, which can take a couple of minutes before you hear the burner light. Leave it at least five minutes before deciding it hasn't worked.

Why does my boiler need resetting after a power cut?

Some boilers go into lockout if the power drops while they are running. After a power cut, check the clock or timer has not lost its settings, check the boiler has power, then reset it once. If it locks out again, the power cut may have coincided with a separate fault.

Will resetting my boiler fix low pressure?

No. If the gauge is below about 1 bar the boiler will lock out again until you repressurise the system through the filling loop. Top it up to around 1 to 1.5 bar first, close the filling loop fully, then reset.

Sources and further reading

Source links checked 27 September 2026. Scheme rules and manufacturer instructions can change; use the current official guidance for your account or exact appliance.

Boiler won't stay on after a reset?

Have the make, model and the exact fault code or light pattern ready. We'll talk you through it and confirm the price before a Gas Safe engineer starts any work.

£60 call-out for short diagnostic visits, waived on jobs taking over 2 hours. Specialist investigation scope and charges should be agreed before booking.

Call 020 7870 3200Request a quote online →

Trusted Plumber London

Heating guides editorial team

Homeowner guidance on boilers and heating controls. Work inside the boiler casing or on the gas side must be carried out by a Gas Safe registered engineer.