Vented vs Unvented Cylinder: The Difference and Which to Choose
A vented cylinder is fed by a cold water tank in the loft; an unvented cylinder runs straight off the mains at much higher pressure. How they compare on pressure, space, safety rules and upkeep, and which suits your home.
A vented cylinder is fed by a cold water storage tank in the loft, so its pressure depends on how high the tank sits above your taps. An unvented cylinder is fed straight from the mains, so it delivers hot water at close to mains pressure and needs no loft tank. Unvented gives stronger showers and frees up the loft, but it needs good mains pressure and flow, a G3-qualified installer and an annual check. Vented is simpler and cheaper to maintain, and it still works well where mains pressure is poor.
Key Takeaways
- Vented: fed from a loft tank by gravity; pressure depends on the height of the tank above the outlet.
- Unvented: fed from the mains at much higher pressure, with no loft tank.
- Unvented only works well if your incoming mains pressure and flow are good enough; test before you choose.
- Unvented cylinders over 15 litres must be installed by a G3-qualified engineer and notified to building control.
- Unvented systems have safety valves and an expansion vessel or air gap that need checking every year.
The difference comes down to where the cold water comes from. A vented cylinder is fed by gravity from a cold water storage tank in the loft, so the pressure at your taps depends on how high that tank sits above them. An unvented cylinder is sealed and fed straight from the mains, so it delivers hot water at close to mains pressure and needs no loft tank. Unvented gives stronger showers and more space, but it relies on a good mains supply and has stricter safety rules. Vented is simpler, cheaper to maintain, and still the better choice in some homes.
If you are not sure whether you need a cylinder at all, our combi vs system boiler guide covers when a combi with no cylinder is the better fit.
How each cylinder works
Vented (open vented) cylinder
Cold water from the mains fills a storage tank in the loft. That tank feeds the cylinder by gravity. The cylinder heats the water with a coil from the boiler, an immersion heater, or both. An open vent pipe runs from the top of the cylinder back up over the tank, so if the water ever overheats it has somewhere to go. The system is never under more pressure than the weight of water above it.
As a rough guide, every metre of height between the bottom of the loft tank and the outlet gives about 0.1 bar of pressure. A shower one floor below the loft may only get 0.2 to 0.3 bar, which is why vented systems often have a shower pump.
Unvented cylinder
The cylinder is connected directly to the incoming mains. A pressure reducing valve brings the mains down to a steady working pressure, usually around 3 bar depending on the model, and the cylinder stores and heats the water under that pressure. Because the system is sealed, it needs safety devices: a temperature and pressure relief valve, an expansion vessel or internal air gap to take up the expansion of heated water, and a discharge pipe with a tundish so any release can be seen and runs safely to a drain. Megaflo is a well-known brand; our article on Megaflo air gap problems covers one type of unvented design.
Vented vs unvented: side-by-side
| Vented | Unvented | |
|---|---|---|
| Water supply | Loft tank, by gravity | Direct from the mains |
| Hot water pressure | Low; depends on tank height | High; close to mains pressure |
| Loft tank needed | Yes | No |
| Works with weak mains | Yes | No; needs good pressure and flow |
| Shower performance | Often needs a pump | Strong without a pump |
| Who can install it | A competent plumber | A G3-qualified engineer, notified to building control |
| Annual check | Recommended, simpler | Required by most manufacturers |
| Discharge pipe | Not needed | Needed, with a safe route to a drain |
| Frost and loft risk | Loft tank and pipes can freeze or leak | No loft tank to worry about |
When a vented cylinder makes sense
- Your mains pressure or flow is poor. Many older London streets and upper-floor flats have weak mains. An unvented cylinder cannot deliver more than the mains gives it, so a vented system with a suitable pump may perform better. Our guide to low water pressure at home shows how to test it.
- You are replacing like for like. If the existing vented system works and you are happy with it, a new vented cylinder is the simplest and usually the quickest swap.
- There is no safe route for a discharge pipe. Unvented cylinders need one. In some flats and awkward cupboards there is nowhere suitable to run it.
- You want low maintenance. Vented systems have fewer safety parts to check and fewer things to go wrong.
When an unvented cylinder makes sense
- You want better showers. With good mains, an unvented cylinder gives strong, balanced pressure at every tap and shower without a pump.
- You have more than one bathroom. Two showers running at once is where unvented systems shine, provided the mains flow can keep up.
- You want the loft back. Taking out the tank frees space for a loft conversion or storage and removes the risk of a loft tank leaking or freezing.
- You are renovating anyway. If walls and floors are open, it is the best time to run the discharge pipe and make any pipework changes.
Safety rules for unvented cylinders
Under Part G of the Building Regulations, an unvented hot water system with a capacity over 15 litres has to be installed by someone competent to do it, which in practice means an engineer holding a G3 unvented qualification, and the installation has to be notified to building control. That is because a sealed cylinder storing hot water under pressure is dangerous if its safety devices fail.
Once it is in, most manufacturers ask for an annual check. The engineer tests the relief valves, checks the expansion vessel charge or air gap, checks the pressure reducing valve and makes sure the discharge pipe and tundish are clear. Water running through the tundish is a warning sign, not a normal drip; see unvented cylinder tundish dripping for what it means.
Both types of cylinder should store water at 60ยฐC or above to control Legionella, with thermostatic mixing valves where scalding is a risk.
Switching from vented to unvented
Most vented systems can be converted to unvented if the mains supply is good enough. The job involves fitting the new cylinder, adding the safety devices and discharge pipe, removing or decommissioning the loft tank, and checking that the existing pipework and taps can take mains pressure. Older joints and cheap taps that were fine at low pressure can leak when the pressure goes up, so a good installer checks them before the switch.
It is also the right moment to check the cylinder is the right size for your household. Our guide on what size hot water cylinder you need goes through the numbers.
Want an honest view on vented or unvented?
We'll test your mains pressure and flow, look at where the cylinder and discharge pipe would go, and tell you which system will actually work better in your home.
๐ Call 020 7870 3200Or read about our unvented cylinder installation and repair and hot water cylinder replacement.
Frequently Asked Questions
What is the difference between a vented and an unvented cylinder?
A vented cylinder is fed by gravity from a cold water tank in the loft and has an open vent pipe, so its pressure is low and depends on the height of the tank. An unvented cylinder is sealed and fed directly from the mains, so it delivers hot water at much higher pressure without a loft tank.
Is an unvented cylinder better than a vented one?
Not always. Unvented gives better pressure and frees loft space, but only if the incoming mains pressure and flow are good. In a home with weak mains, a vented cylinder with a pump can give a better result. Vented systems are also simpler and cheaper to look after.
How can I tell if my cylinder is vented or unvented?
A vented cylinder is usually copper, often with foam insulation, and has a cold water tank in the loft feeding it. An unvented cylinder usually has a solid outer casing, a label, a pressure relief valve, a small expansion vessel or none if it uses an internal air gap, and a tundish on the discharge pipe. If there is no cold tank in the loft, it is likely unvented or you have a combi.
Do unvented cylinders need servicing?
Yes. Manufacturers ask for an annual check by a G3-qualified engineer, covering the pressure relief and temperature relief valves, the expansion vessel charge or air gap, the pressure reducing valve and the discharge pipe. Missing the service can affect the warranty.
Can I replace a vented cylinder with an unvented one?
Usually, if your mains pressure and flow are good enough and there is a safe route for the discharge pipe. The loft tank can then be removed. A G3-qualified engineer should test the mains and survey the property before you commit.
Sources and further reading
Source links checked 27 September 2026. Scheme rules and manufacturer instructions can change; use the current official guidance for your account or exact appliance.