Ideal Boiler Fault Codes: F1, F2, L2 and What to Do

What the common Ideal boiler fault codes mean, from F1 low pressure and F2 flame loss to L1 overheat, L2 ignition lockout and LC, with the checks you can safely make before calling a Gas Safe engineer.

Quick Answer

Ideal boilers show two kinds of code. F codes are faults the boiler reports while it waits: F1 is low water pressure, F2 is flame loss, F3 is a fan fault, F4 and F5 are the flow and return temperature sensors, and F6 is the outside sensor. L codes are lockouts, where the boiler has shut itself down for safety: L1 is overheat or no water flow, L2 is ignition lockout and L6 is a false flame lockout. LC means the boiler has been reset five times in 15 minutes. You can safely check the pressure gauge (1 to 1.5 bar), whether other gas appliances work, a prepayment meter and, in frosty weather, the condensate pipe. Restart once. If the same code comes back, book a Gas Safe engineer.

Key Takeaways

  • F1 and L1 are the codes you can most often clear yourself: check the gauge reads 1 to 1.5 bar.
  • F2 and L2 mean the boiler couldn't keep or get a flame. Check the gas supply and, in freezing weather, the condensate pipe.
  • F3, F4, F5, F6 and L6 point to a part such as the fan or a sensor, which needs an engineer.
  • LC means too many resets. Stop pressing restart and find the cause.
  • Codes differ slightly between Ideal ranges, so check the table in your own user guide.
Ideal boiler showing a fault code?

Tell us the model on the front of the boiler, the exact code and whether it came back after one restart. We'll arrange a Gas Safe engineer and confirm the price before any work starts.

Discuss an Ideal boiler repair →

Ideal boiler fault codes come in two groups. F codes are faults the boiler has detected: F1 is low water pressure, F2 is flame loss, F3 is a fan fault, F4 and F5 are the flow and return temperature sensors, and F6 is the outside sensor. L codes are lockouts, where the boiler has shut down for safety: L1 is overheat or no water flow, L2 is ignition lockout and L6 is false flame lockout. LC means it has been reset five times in 15 minutes. Most homeowners see F1, L1 or L2, and those are the ones you can often clear yourself by checking the pressure, the gas supply and the condensate pipe. If a code comes back after one restart, it needs a Gas Safe engineer.

F codes and L codes

An F code usually means the boiler has spotted a problem and is waiting. Fix the cause, such as low pressure, and it often starts again by itself or after a restart. An L code means the boiler has locked out. It tried to do something, such as light the burner, failed in a way that could be unsafe, and shut down. It won't run until you press restart.

Before you look anything up, note the model name on the front of the boiler (Logic, Logic+, Vogue, Instinct, Exclusive and so on) and write the code down exactly. Ideal uses much the same codes across its ranges, but a few differ between older and newer models, so the fault table in your own user guide has the final word.

Ideal fault codes at a glance

CodeWhat Ideal says it meansWhat you can check
F1Low water pressureGauge should read 1 to 1.5 bar. Top up with the filling loop.
F2Flame lossOther gas appliances, gas meter, prepayment credit.
F3Fan faultRestart once. If it returns, call an engineer.
F4Flow thermistor (temperature sensor)Restart once, then engineer.
F5Return thermistorRestart once, then engineer.
F6Outside sensor faultOnly on boilers with a weather sensor fitted. Restart, then engineer.
F7Low mains voltageAn electrical supply problem, not a boiler part. Ideal's guide says to contact an electrician or your electricity supplier.
L1Flow temperature overheat or no water flowPressure at 1 to 1.5 bar, radiator valves open.
L2Ignition lockoutCondensate pipe, other gas appliances, meter and credit.
L6False flame lockoutRestart once, then engineer.
LCFive resets within 15 minutesTurn the power to the boiler off and on. Stop resetting.
dDiverter valve set to mid-position for servicing (Logic Code Combi)Turn the knobs fully clockwise, switch the power off and on, press restart.

Sources: Ideal's fault code FAQ and the fault code table in the Logic Code Combi ESP1 user guide. On some models L5 appears alongside a return sensor fault, while Ideal's general list uses L5 for too many resets, which is why checking your own manual matters.

F1 and L1: pressure and water flow

F1 means the water pressure in the heating system has dropped too low for the boiler to run safely. Look at the gauge on the front or underneath the boiler. Ideal's guide says it should read between 1 and 1.5 bar with the heating cold. If it's lower, top it up using the filling loop, the braided hose or key under the boiler, following your user guide. Our guide on how to repressurise a boiler walks through it step by step.

Topping up is the easy part. If you have to do it again within days or weeks, water is escaping somewhere: a weeping radiator valve, a pressure relief valve discharging outside, a failed expansion vessel or a leak under the floor. See why a boiler keeps losing pressure for how to narrow that down, and our full Ideal F1 guide.

L1 means the water leaving the boiler got too hot, usually because not enough water was moving through it. Ideal's first check is the same: pressure between 1 and 1.5 bar. Also make sure the radiator valves haven't all been turned off, because a boiler with nowhere to send its heat will overheat. If the pressure is right and L1 keeps coming back, the usual causes are a failing pump, sludge, a blocked filter or a sensor, which is engineer territory. More in our Ideal L1 guide.

F2 and L2: flame loss and ignition

Both codes are about the burner. F2 means the boiler lit, then lost the flame. L2 means it tried to light, didn't detect a flame and locked out. The checks you can make are the same for both:

  1. Check that other gas appliances, such as the hob, are working. If none are, the problem is the gas supply rather than the boiler.
  2. Check the gas meter is on and, if you have a prepayment meter, that it has credit. A recent top-up after running out can leave air in the supply.
  3. For L2 in cold weather, check the condensate pipe. Ideal's user guide says a blocked condensate pipe makes a gurgling noise before the boiler locks out on L2. It's the white or grey plastic pipe running outside to a drain. Pour warm, not boiling, water over the frozen section at ground level only.
  4. Restart the boiler once.

If other gas appliances work, the condensate pipe is clear and the code returns, the cause is usually inside the boiler: the ignition electrode, flame sensing, the gas valve or the PCB. That work needs a Gas Safe engineer. Our Ideal L2 guide and Ideal F2 guide go into more detail, and our condensate pipe page covers a pipe that keeps freezing.

If you smell gas at any point, stop. Don't restart the boiler or use switches. Open windows, turn off the gas at the meter if you can, leave the property and call the National Gas Emergency Service on 0800 111 999. See our guide on what to do if you smell gas.

F3 to F6 and L6: parts faults

These codes point at a specific component rather than something you can adjust from outside the boiler:

  • F3, fan fault. The fan pushes air through the burner and out of the flue. If the boiler can't confirm the fan is running at the right speed, it won't light. A fan that has started to whine or rattle can be an early sign.
  • F4 and F5, flow and return thermistors. These sensors tell the boiler the water temperature. A faulty sensor or loose connection gives a reading the boiler can't trust.
  • F6, outside sensor. Only relevant if a weather compensation sensor has been fitted on an outside wall. A damaged cable or sensor triggers it.
  • L6, false flame lockout. The boiler detected a flame when there shouldn't be one. It's a safety lockout and needs checking.

For all of these, Ideal's advice is to restart the appliance once and, if it fails to operate, contact Ideal while the boiler is under warranty or a Gas Safe registered engineer if it isn't. Don't open the casing. HSE's guidance explains how to check an engineer is registered for the work.

Restarting, and what LC means

On most Ideal boilers you restart by pressing the restart button. On some models you turn the control knob to the reset position for a few seconds. Our guide on how to reset a boiler covers the general method.

Restart once, after you've dealt with the likely cause. Pressing restart again and again doesn't fix anything, and Ideal boilers count it: five resets within 15 minutes shows LC. Ideal's guide says to turn the electrical supply to the boiler off and on at that point, and to call an engineer if it still won't work.

When to call an engineer

Call a Gas Safe engineer when:

  • F1 comes back within a few days of topping up, or the pressure won't hold.
  • L1 returns with the pressure correct and radiators open.
  • F2 or L2 returns when other gas appliances work and the condensate pipe is clear.
  • You see F3, F4, F5, F6 or L6 after one restart.
  • LC appears and switching the power off and on hasn't helped.

If the boiler is still under Ideal's warranty, contact Ideal first, as the warranty terms may require it. Outside warranty, our engineers repair Ideal boilers across London. See our boiler repair and boiler lockout services.

We charge £95 an hour for labour, plus a £60 call-out that's waived when the job runs over 2 hours. Parts are extra, and we confirm the price before any work starts. The pricing page explains how jobs are charged. For codes from other makes, see our Worcester, Baxi and Vokera code guides.

Ideal boiler stuck on a code?

Tell us the model and the code. We'll arrange a Gas Safe engineer and confirm the price before starting.

📞 Call 020 7870 3200

Or see our boiler repair service and pricing.

Frequently Asked Questions

What is the most common Ideal boiler fault code?

F1, low water pressure, is the one most homeowners see, and it's often fixable by topping the system up to 1 to 1.5 bar with the filling loop. L2, ignition lockout, is the other common one, especially in freezing weather when the condensate pipe can freeze.

What is the difference between F codes and L codes on an Ideal boiler?

F codes are faults the boiler has detected, such as low pressure or a failed sensor. L codes are lockouts: the boiler has shut itself down for safety and won't run again until the cause is dealt with and it's restarted.

How do I reset my Ideal boiler?

Press the restart button, or on some models turn the control knob to the reset position, as your user guide describes. Deal with the likely cause first, such as low pressure. If LC appears, the boiler has been reset five times in 15 minutes: turn the electrical supply off and on, and if it still won't run, call an engineer.

What does LC mean on an Ideal boiler?

LC means the boiler has been reset five times within 15 minutes. It's a sign the underlying fault hasn't been fixed. Ideal's guide says to turn the electrical supply off and on, and if the boiler still fails to work, contact Ideal under warranty or a Gas Safe engineer.

Can I fix an Ideal boiler fault code myself?

You can check the pressure and top it up, check the gas supply and prepayment meter, thaw a frozen condensate pipe at ground level, and restart the boiler once. Anything that means opening the boiler casing, such as a fan, sensor, electrode or PCB fault, must be done by a Gas Safe registered engineer.

Sources and further reading

Source links checked 28 September 2026. Scheme rules and manufacturer instructions can change; use the current official guidance for your account or exact appliance.

Ideal boiler showing a fault code?

Tell us the model on the front of the boiler, the exact code and whether it came back after one restart. We'll arrange a Gas Safe engineer and confirm the price before any work starts.

£60 call-out for short diagnostic visits, waived on jobs taking over 2 hours. Specialist investigation scope and charges should be agreed before booking.

Call 020 7870 3200Request a quote online →

Trusted Plumber London

Boiler guides editorial team

Homeowner guidance based on the manufacturer and HSE publications below. Work inside a gas boiler must be carried out by a Gas Safe registered engineer.